Organ-on-chip for blood-brain barrier research

Jul 17th 2018

By combining the principles of microfluidics, microfabrication and cell culturing techniques, a new generation of laboratory platforms has emerged, known as “organ-on-chip”. Organ-on-chip systems are microfluidic devices containing living cells. These microfluidic devices can better recapitulate microenvironments compared to previous in vitro models. Microfluidic devices are especially suitable for modeling biological barriers, such as the blood-brain barrier, as they can model blood flow.  

 

Structure and function of the blood-brain barrier

 

The blood-brain barrier (BBB) is the boundary layer of cells that lines the brain micro vessels and separates blood from brain interstitial fluids. The main function of the blood-brain barrier is to act as a physical and metabolic barrier by allowing selective transport of nutrients through, but preventing toxic substances in the blood from entering the brain.

The BBB is made up of specialized endothelial cells which are surrounded by a basement membrane and four other types of cells: astrocytes, pericytes, neurons and microglia. These five types of cells and the basement membrane together make up the neurovascular unit (figure 1) [1]. Sealing protein complexes called tight junctions are formed between adjacent endothelial cells of the BBB. As a result, cells are held in close proximity to each other, thereby occluding the intracellular spaces and preventing paracellular transport. This high barrier tightness is characteristic of the BBB, and crucial for maintaining brain homeostasis. A local disruption of the barrier tightness, resulting in a leakage through the barrier, is associated with several diseases of the central nervous system (CNS) [2]. Understanding and overcoming the BBB is essential for treatment of diseases on the CNS. Drug delivery systems that can temporarily open the barrier, allowing medication to pass through and reach the brain, is a key research area for the treatment of CNS diseases.

Figure 1. Illustration of the neurovascular unit [1]

 

In vitro models of the blood-brain barrier

 

In artificial environments conditions can be kept under high control and specific behaviors can be independently studied with little interference of other factors. Traditionally, the BBB has been reconstructed in vitro as static models using conventional cell culture setups. Microfluidic organ-on-chip devices offer solutions to many of the shortcomings of previous in vitro models. These devices can be designed with more realistic architectures and their small dimensions better represent the geometry of the capillaries in the neurovascular unit. Further, by employing microfluidics instead of conducting experiments in a bulk solution, the models can display physiological phenomena such as fluid flows and shear stresses. Another advantage of BBB-on-chip models is that sensors for real-time monitoring can be integrated [3].

 

Blood-brain barrier on a microfluidic chip

 

Two of the early microfluidic devices that have pioneered the development of BBB-on-chip and provided proof-of-principle for several promising concepts are presented below. Some important design aspects and validation parameters to consider when developing an organ-on-chip device to study the BBB will also be introduced. Today, ready-to-use chips for organ-on-chip applications are commercially available or can be ordered custom-made.

 

Discover Darwin microfluidics’ microfluidic chips for organ-on-chip applications:

https://darwin-microfluidics.com/collections/microfluidic-organ-on-a-chip

 

To our knowledge, Booth et al. were the first to published a BBB on chip model in 2012 [4] with a follow-up paper in 2014 [5]. Their device, shown in figure 2, comprises two crossing channels in layers of PDMS, with a depth of 200 µm and a width of 2 mm and 5 mm respectively. The two channels were separated by a porous polycarbonate membrane covered by fibronectin. The channel layers were covered by glass slides with thin film Ag/AgCl electrodes with a four-point sensing structured placed over the membrane. Mouse endothelial cells (b.End3) and murine astrocytes (C8D1A) were cocultured on opposite sides of the membrane. A flow rate of 2.6 mL/min was applied in both channels, which according to calculations presented in the paper, corresponded to a shear stress of 2 mPa on the endothelial cells. The transendothelial electrical resistance (TEER) was measured to 180-280 Vcm2 with the integrated thin film electrodes. Further, the tight junction protein ZO-1 was identified with immunofluorescence and permeability studies were performed to confirm the barrier function.

Figure 2. Schematic illustration and picture of the BBB-on-chip developed by Booth et al. (Reprinted from Booth et al. [5])

 

Another fully integrated BBB device was published by Griep et al. in 2013 [6]. The device was made up of two layers of PDMS comprising channels with a width of 500 µm and depth of 100 µm, with a polycarbonate membrane coated with collagen between. Human cerebral microvascular endothelial cells (hCMEC/D3) were cultured on top of the membrane. They used four platinum wires to monitor the TEER value over 7 days from impedance spectroscopy measurements. They obtained an average TEER value of 28 Vcm2 ± 1.3 SEM).  They observed an increase in TEER, up to 120 Vcm2, when a flow rate of 2.5 mL/h was applied, corresponding to a calculated shear stress of 0.58 Pa.

Figure 3. Schematic illustration of the chip layers (a) and the assembled chip (b), and picture of the BBB-on-chip developed by Griep et al. (Reprinted from Griep et al. [6])

 

Chip material for organ-on-chip

 

PDMS has been used extensively to fabricate organ-on-chip devices. Some of the advantages of PDMS include being biocompatible and transparent (240 nm - 1100 nm), cheap and easy to handle, can be molded with high resolution and can bond to glass or PDMS [7]. It is however highly hydrophobic which can be problematic when filling the channels or to obtain tight bonding for non-leaking chips. Furthermore, it is difficult to deposit electrodes on the surface of PDMS, and glass is therefore often used in devices with patterned thin film electrodes.

NPG72 is a novel thermoplastic material with great promise for organ-on-a-chip applications. It has the same advantages as PDMS, but unlike PDMS which takes several hours to mold, a NPG72 chip can be fabricated in minutes.

Discover the material NPG72 here https://darwin-microfluidics.com/products/npg72-starter-pack

 

Cells in blood-brain barrier on chip models

 

The type of cells used are of great importance to construct models of biological relevance. It is however still unclear exactly how the different cells of the neurovascular unit contribute to the barrier function [8]. To mimic the human BBB, using human cells would obviously be the most predictive. Human brain capillary endothelial cell have been widely characterized but have low availability and reproducibility [1]. Recent advancements in deriving human induced pluripotent stem cells (hiPSC) holds great promise to overcome such difficulties [9].

Co-culturing endothelial cells with other cells from the neurovascular unit is expected to be a more physiologically relevant representation, as these cells also influence the formation and maintenance of the barrier [10]. Several studies of co-cultures in microfluidic BBB models have already been published, mainly endothelial cells with astrocytes [4] [11], but also with neurons [12] and pericytes. Astrocytes and endothelial cells are not in direct contact with each other, but separated by the basal lamina. In microfluidic devices they can be cultured on separate sides on the membrane. However, it the membrane in the device is too thick, the cell-cell contact will be limited.  To mimic the 3D environment of the extracellular matrix, hydrogels have been used as cell seeding scaffolds inside microfluidic chambers [12].

 

Shear stress on endothelial cells

 

The endothelial cells of the BBB in the neurovascular unit are subjected to a force normal to the vessel wall due to blood pressure, as well as a shear stress resulting from the blood flow, in the direction of the flow. Shear stresses have already been reported to influence endothelial cell morphology and function, and to have a positive effect on barrier formation [13]. Organ-on-chip devices have the great advantage of being suited for incorporation of fluid flow, unlike other types of devices. Living blood vessels have circular cross sections, while microfluidic devices typically have rectangular cross sections. In a tube with circular cross section, the shear stress will be equal and uniform on the walls due to the cylindrical symmetry. In the case of a rectangular cross section however, the shear stress will not be uniform. To achieve the most uniform stress in a rectangular cross section, a flow profile as flat as possible can be achieved by designing the channels to have a channel height much smaller than the channel width [14]. The physiological shear stress for brain capillaries is 0.3-2 Pa [2].

 

Transendothelial electrical resistance (TEER)

 

TEER describes the resistance across a cellular barrier, and is often used as a validation parameter to control if endothelial cells in BBB models form tight junction complexes [15]. If the endothelial cells are growing properly and form tight junctions to adjacent cells, the intercellular spaces of the cell layer are occluded and the flow of current through is restricted [16]. This induces a higher resistance to current, which is reflected in higher TEER values. TEER is often expressed normalized to the membrane area in the unit Ωcm2, as in the below, to facilitate direct comparison to other models.